Preset Number Selection of the number of preset memory bank to which the data will be stored (Bulk Dump Data Load) or from which the data will be read (Bulk Dump Data Request).
VCO PITCH - Key Shift The instrument's VCO tone range can be transposed with a help of this parameter:

VCO PITCH - Aftertouch Bend Parameter sets the range of bend (detune) allowed for the Channel Aftertouch command. Maximal detune is +-4 semitones.
VCO MOD - Wave Parameter sets the waveform of the internal software LFO for the VCO modulation (frequency sweep):

VCO MOD - Polarity Parameter sets the polarity (direction) of the VCO frequency modulation by the internal LFO:

VCO MOD - Rate Parameter sets the rate of speed of the internal LFO:

VCO MOD - Wheel Amount Parameter sets the VCO modulation amount for the Modulation Wheel (CC1) command.
VCO MOD - Aftertouch Amount Parameter sets the VCO modulation amount for the Channel Aftertouch command.
VCO MOD - Retrig Parameter allows the syncing of the internal LFO to each of received Note-On commands.
VCF CUTOFF - Frequency Parameter limits the basic cutoff frequency of the VCF.
VCF CUTOFF - Key Follow Parameter sets the level and direction of the VCF affecting by received MIDI note number.
VCF CUTOFF - Velocity Amount Parameter sets the level of the VCF affecting by velocity of the MIDI Note-On commands.
VCF CUTOFF - Aftertouch Amount Parameter sets the level of the VCF affecting by the Channel Aftertouch commands.
VCA LEVEL - Key Follow Parameter sets the level and direction of the VCA affecting by received MIDI note number.
VCA LEVEL - Velocity Amount Parameter sets the level of the VCA affecting by velocity of the MIDI Note-On commands.
VCA LEVEL - Aftertouch Amount Parameter sets the level of the VCA affecting by Channel Aftertouch commands.
VCA LEVEL - Volume Mode Parameter selects the method of a volume control for the instrument's VCA via Control Changes Volume (CC7) and Expression (CC11) commands.
CONTROL - Bender Mode Parameter selects the method of control for the instrument's bender.
CONTROL - Indicator Mode Parameter selects the function of the interface's LED indicator.
Bulk Dump Data Load - Generate button Generated Bulk Dump message changes the values of all parameters in a permanent preset memory bank. Number of the requested preset memory bank can be set in the "Preset Number" box. Requested values of all preset parameters must be set before the Bulk Dump Message is generated.
Bulk Dump Data Request - Generate button Generated Bulk Dump message is inquiry for the content of a preset memory bank. The Number of requested preset memory bank must be set in the "Preset Number" box before the Bulk Dump Message is generated. Immediately after the message receiving the interface sends the Bulk Dump Data Save / Load message as reply.
|