Select Device ID This value must be the same as MIDI channel number (chosen by switch on front panel of the device). You can select "Universal" value too - a message will be accepted independently on MIDI channel number in that case.
Select Preset No. This value must be selected when "Bulk Dump Load" message is generated (changes of part of preset memory bank).
DCO Note Shift This parameter transposes the keyboard in range from -36 to +24 semitones. The lowest key on the instrument is equal to MIDI Note Nr. 36 if the DCO Note Shift function is not applied.
DCO Mode This parameter selects operating mode of the DCO. Poly is standard working mode, Chord is a special mono mode.
LFO Sync Internal LFO runs in free mode if this parameter is set to "Free" or the LFO is synchronized with MIDI clock if this parameter is set to "MIDI Clk".
LFO Wave This parameter determines the waveform of internal LFO.
LFO Rate The effect of this parameter depends on the value of "VCF Vibrato Sync" parameter: LFO Sync = Free - frequency of LFO is constant in range from 0,2 Hz to 10,0 Hz LFO Sync = MIDI Clk - frequency of LFO is determined by the tempo of the song and can be set from 1/32 to 64/32 note in 1/32 step
LFO Delay The effect of this parameter depends on value of "VCF Vibrato Sync" parameter: LFO Sync = Free - delay between pressing any key and activation of the LFO is constant in range from 0 sec to 12,5sec LFO Sync = MIDI Clk - delay between pressing any key and activation of the LFO is determined by tempo of song and can be set from 0 to 64/32 note in 1/32 step
LFO Retrigger Start of the LFO period is synchronized with each key pressed if this parameter is set to "On". Only the first pressed key after a pause synchronizes the start of the LFO period if this parameter is set to "Off".
VCF Control Mode Instrument's VCF can be controlled by the MIDI Control Change (its number is defined by the system parameter "VCF Controller") if the parameter is set to "Controller". It can be controlled directly by Pitch Wheel command if the parameter is set to "Pitch Wheel". All other "VCF" parameters are ignored in this case. If the parameter is set to "Normal", all other "VCF" parameters for VCF control are accepted.
VCF Pitch Wheel Range This parameter adjusts the range of the Pitch Wheel VCF modulation if VCF Control Mode parameter is set to "Pitch Wheel".
VCF Cutoff This parameter sets the basic level of VCF frequency.
VCF LFO Amount Level of the VCF modulation by the internal vibrato effect can be set by this parameter. Vibrato has no effect if the parameter value is set to 0.
VCF MOD Amount Level of the VCF modulation by the "Modulation Wheel" (MIDI Control Change No. 1) can be set by this parameter. "Modulation Wheel" has no effect if the parameter value is set to 0.
VCF Velocity Polarity Direction of the VCF MIDI Note velocity modulation can be set by this parameter. Direct proportion between VCF frequency and MIDI Note velocity is set up, if this parameter is set to "Positive Last" or "Pos. Average"; inverse proportion is set up, if this parameter is set to "Negative Last" or "Neg. Average". Velocity of last received note only is applied if the parameter is set to "Positive Last" or "Negative Last". Average value of velocities of all active notes is applied if parameter is set to "Pos. Average" or "Neg. Average".
VCF Velocity Amount Level of modulation of the VCF by velocity can be adjusted by this parameter. Velocity of a MIDI Notes has no effect if the value is set to 0.
VCF Aftertouch Polarity Direction of Key Aftertouch and Channel Aftertouch VCF modulation can be set by this parameter. Direct proportion between VCF frequency and Key Aftertouch or Channel Aftertouch messages is set up, if this parameter is set to "Positive Last" or "Positive Avrg"; inverse proportion is set up, if this parameter is set to "Negative Last" or "Negative Avrg". Only last received value of Key Aftertouch is applied if parameter is set to "Positive Last" or "Negative Last". Average value of the Key Aftertouch of all active notes is applied if the parameter is set to "Positive Avrg" or "Negative Avrg".
VCF Key Aftertouch Amount Level of Key Aftertouch VCF modulation can be adjusted by this parameter. Key Aftertouch message has no effect if the value is set to 0.
VCF Chnl Aftertouch Amount Level of Channel Aftertouch VCF modulation can be adjusted by this parameter. Channel Aftertouch message has no effect if the value is set to 0.
ARPG Sync This parameter determines the source of the trigger pulses for the instrument's arpeggiator: Free - trigger pulses are generated by the internal clock generator, the frequency depends on "ARPG Rate" parameter only. MIDI Clk - trigger pulses are generated by the internal generator synchronized with MIDI clock, the frequency depends on "ARPG Rate" parameter Controller and on tempo of played song simultaneously. Controller - generated trigger pulses depends on changes of the MIDI Control Change (its number is defined by system parameter "ARPG Controller").
ARPG Rate The result of setting of this parameter depends on value of "ARPG Sync" parameter: ARPG Sync = Free - frequency of the arpeggiator is constant in the range from 0,2 Hz to 10,0 Hz. ARPG Sync = MIDI Clk - frequency of the arpeggiator is determined by the tempo of played song and can be set from 1/32 to 64/32 in 1/32 step. ARPG Sync = Controller - arpeggiator is not affected by this parameter.
ARPG Key Chase Start of the arpeggiator period pulses is synchronized with each key pressed if this parameter is set to "On". Only the first pressed key after a pause synchronizes the start of the arpeggiator period if this parameter is set to "Off". This parameter has no effect if "ARPG Sync" parameter is set to "Controller".
SysEx Msg - Select Hex Byte Form Text form of generated hexadecimal bytes can be chosen by this select-box. Requested form must be selected before any "Generate" or "Generate All" button is pressed.
SysEx Msg - Select Delimiter Delimiter between generated hexadecimal bytes can be chosen by this select-box. Requested delimiter must be selected before any "Generate" or "Generate All" button is pressed.
|